6 standard devices with a power of 55 kw, 1 mounting with fixing brackets (standard), Standard devices with a power of 55 kw – Lenze E82xVxxxKxxxxx User Manual
Page 89: Mounting with fixing brackets (standard), Mechanical installation

Mechanical installation
Standard devices with a power of 55 kW
Mounting with fixing brackets (standard)
l
89
EDS82EV903−3.0
5.6
Standard devices with a power of 55 kW
5.6.1
Mounting with fixing brackets (standard)
Mounting material required from the scope of supply:
Description
Use
Quantity
Fixing bracket
Drive controller fixing
4
Hexagon head cap screw M8 × 16 mm
(DIN 933)
Mounting of fixing bracket to the drive controller
4
Washer
Æ 8.4 mm (DIN 125)
For hexagon head cap screw
4
Spring washer
Æ 8 mm (DIN 127)
For hexagon head cap screw
4
Controller variant "2xx" (without fully assembled footprint filter)
For this mounting variant you require controller type E82EVxxxK4B2xx.
)
Note!
Before assembling the controller, please read the documentation for the
components connected on the supply side (mains choke, filter).
a
c1
e
b1
d
d1
b
l
c
³ 50 mm
³ 50 mm
g
m
k
0
³ 100 mm
³ 100mm
9300vec175
Fig. 5−23
Standard mounting with fixing brackets 55 kW
Loosen both screws to be able to remove the housing cover. The assembly kit is located under
the housing cover.
Installation of mounting angles
Dimensions
0
Arrange the controllers side by side with spacing to be able to disassemble the eyebolts.
Dimensions [mm]
8200 vector
a
b
b1
c
c1
d
d1
e
1)
g
k
m
E82EV553K4B2xx
340
672
591
28.5
283
615
38
285
11
28
18