Important codes for quick commissioning
l
215
EDS82EV903 EN 3.0
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0002
*
s
uSEr
Parameter set
management
0
0
Ready
PAR1 ... PAR4:
l
Parameter sets of the controller
l
PAR1 ... PAR4 also contain the
parameters for the function
modules standard I/O,
application I/O, AS interface,
system bus (CAN)
FPAR1:
l
Module−specific parameter set
of the fieldbus function
modules INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
l
FPAR1 is saved in the function
module
^ 368
Restoring the
delivery status
1
Lenze setting
ð PAR1
Restore the delivery status in the
parameter set selected
2
Lenze setting
ð PAR2
3
Lenze setting
ð PAR3
4
Lenze setting
ð PAR4
31
Lenze setting
ð FPAR1
Restore the delivery status in the
fieldbus function module
61
Lenze setting
ð PAR1 + FPAR1
Restore the delivery status in the
selected parameter set of the
controller and in the fieldbus
function module
62
Lenze setting
ð PAR2 + FPAR1
63
Lenze setting
ð PAR3 + FPAR1
64
Lenze setting
ð PAR4 + FPAR1
C0002
*
s
uSEr
(Cont.)
Transferring
parameter sets
with the
keypad
By means of the keypad you can
transfer the parameter sets to
other controllers.
During the transmission the access
to the parameters via other
channels is inhibited!
Keypad
ð controller
Overwrite all available parameter
sets (PAR1 ... PAR4, if required
FPAR1) with the corresponding
data of the keypad
70
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
10
with all other function modules