Function library – Lenze E82xVxxxKxxxxx User Manual
Page 351

Function library
Free interconnection of digital signals
Free configuration of digital outputs
l
351
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0415
v
(Cont.)
Possible digital signals for C0415
^ 343
AIF control word (AIF−CTRL)
Permanently assigned bits of
AIF−CTRL:
Bit 3: QSP
Bit 7: CINH
Bit 10: TRIP−SET
Bit 11: TRIP−RESET
40
Bit 0
...
...
55
Bit 15
CAN−IN1.W1 or FIF−IN.W1
60
Bit 0
...
...
75
Bit 15
CAN−IN1.W2 or FIF−IN.W2
80
Bit 0
...
...
95
Bit 15
CAN−IN2.W1
100
Bit 0
...
...
115
Bit 15
CAN−IN2.W2
120
Bit 0
...
...
135
Bit 15
Status application I/O
Only active for operation with
application I/O
140
Torque threshold 1 reached
(MSET1=MOUT)
141
Torque threshold 2 reached
(MSET2=MOUT)
142
Limitation of process controller output
reached (PCTRL1−LIM)
143...1
72
Reserved
255
Not assigned (FIXED−FREE)
C0409
v
Configuration −
relay output K2
Output of digital signals to relay K2
l
Relay output K2 only available
with 8200 vector 15 ... 90 kW
l
Only active during operation
with application I/O from
version E82ZAFA...XXVx2x
^ 348
255
255
Not assigned (FIXED−FREE)
Possible digital signals for C0409: see C0415
C0416
v
Level inversion
− digital
outputs
0
0
Level inversion switched off
By entering the sum of the
selected values you can invert
several outputs.
^ 348
1
Relay K1
1
or digital switching output
K1
2
1: applies to version 151
2: applies to version 152
2
X3/A1
4
X3/A2
Only application I/O
8
Relay K2
Relay output K2 only with
8200 vector 15 ... 90 kW