IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0003
*
v
Saving
parameters
non−volatilely
1
0
Do not save parameters in the EEPROM Data loss after mains switch−off
1
Always save parameters in the
EEPROM
l
Active after every mains
connection
l
Cyclic alteration of parameters
via bus module is not
permissible
3
Save your own basic setting in the
EEPROM
Afterwards save parameter set 1
as own basic setting with
C0002 = 9
C0004
*
Bar graph
display
56
1
{Code
no.}
989
l
The bar graph display shows
the selected value in % after
mains connection
l
Range −180 % ... +180 %
56 = device utilisation (C0056)
C0005
v
Fixed
configuration
of analog input
signals
0
Change of C0005 is copied into
the corresponding subcode of
C0412. Free configuration in
C0412 sets C0005 = 255!
Observe the following in case of
configurations with frequency
input:
l
Activate the frequency input
X3/E1, X3/E2 with C0410/24 =
1.
l
Delete all existing signal
connections of the digital
inputs in C0410 used by the
frequency input.
l
Configure frequency input with
C0425 and C0426
^ 328
0
Setpoint for speed control via X3/8 or
X3/1U, X3/1I
1
Setpoint for speed control via X3/8
with setpoint summation via
frequency input
2
Setpoint for speed control via
frequency input with setpoint
summation via X3/8
3
Setpoint for speed control via
frequency input, torque limitation via
X3/8 (power control)
4
Setpoint for sensorless torque control
via X3/8, speed limitation via C0011
Only active if C0014 = −5− (torque
selection)
5
Setpoint for sensorless torque control
via X3/8, speed limitation via
frequency input
6
Controlled operation; setpoint via X3/8
with digital feedback via frequency
input
7
Controlled operation, setpoint via
frequency input X3/E1 with analog
feedback via X3/8
200
All digital and analog input signals are
from the fieldbus function module on
FIF (e.g. INTERBUS, PROFIBUS−DP,
CANopen or DeviceNet)
Sets C0410/x = 200 and C0412/x
= 200
255
Free configuration in C0412
Read only
Do not change C0005 since
settings in C0412 may get lost