Function library – Lenze E82xVxxxKxxxxx User Manual
Page 329

Function library
Free interconnection of analog signals
Free configuration of analog input signals
l
329
EDS82EV903 EN 3.0
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0412
v
Free
configuration
of analog input
signals
Linking analog signal sources to internal analog
signals
A selection in C0005 or C0007 is
copied to the corresponding
subcode of C0412. A change in
C0412 sets C0005 = 255 and
C0007 = 255!
^ 328
1 Setpoint 1
(NSET1–N1)
1
Analog input 1 (AIN1−OUT):
X3/8 (standard I/O)
X3/1U or X3/1I (application I/O)
Either NSET1−N1 or
NSET1−N2 active
Changeover with
C0410/17
Parameter
channel:
C0046
2 Setpoint 2
(NSET1−N2)
1
Parameter
channel:
C0044
3 Additional
setpoint
(PCTRL1−NADD)
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
Acts additively on
NSET1−N1,
NSET1−N2, JOG
values and the
j
functionof the
keypad
Parameter
channel:
C0049
4 Process
controller
setpoint 1
(PCTRL1−SET1)
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
Application of the motor
potentiometer for the selection of
the process controller setpoint
(C0142/4 = 3) is only permissible
in conjunction with the
application I/O!
5 Actual process
controller
value
(PCTRL1−ACT)
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
Parameter
channel:
C0051 if
C0238 = 1,
2
6 Torque
setpoint or
torque limit
(MCTRL1−
MSET)
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
l
Observe C0014!
l
An actual torque
value is not
required.
l
16384
º 100 %
torque setpoint
l
Condition if
selection via
terminal
(C0412/6 = 1, 2 or
4):
– The gain of the
analog input is
set to: C0414/x,
C0426 =
32768/C0011
[%]
Parameter
channel:
C0047
7 Reserved
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
8 MCTRL1−VOLT−
ADD
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module
For special applications only.
Alterations only after consultation
with Lenze!
9 MCTRL1−PHI−
ADD
255
Not assigned (FIXED−FREE) or selection
via keypad or parameter channel of an
AIF bus module