3 display elements and function keys, Display elements and function keys, Parameter setting – Lenze E82xVxxxKxxxxx User Manual
Page 237

Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Display elements and function keys
l
237
EDS82EV903 EN 3.0
9.3.3
Display elements and function keys
Y Z
y
z
T V
S U
d
A
B
b
c
p
SHPRG
Para
Code
Menu
0050
00
50.00_Hz
M C T R L - N O U T
0
1
3
4
5
6
7
8
2
9371BC002
Fig. 9−4
Display elements and function keys of the XT EMZ9371BC keypad
Displays
0 Status displays of standard device
Display
Meaning
Explanation
d
Ready for operation
c
Pulse inhibit is active
Power outputs are inhibited
b
The set current limit is exceeded in motor or
generator mode
B
Speed controller 1 in the limitation
Drive is torque−controlled
(Only active for operation with standard
devices of the 9300 series)
A
Active fault
1 Acceptance of the parameters
Display
Meaning
Explanation
p
Parameter is accepted immediately
Standard device operates immediately
with the new parameter value
SHPRG
p
Parameter must be acknowledged with
T V
Standard device operates with the new
parameter value after being acknowledged
SHPRG
Parameter must be acknowledged in case of
controller inhibit
T V
Standard device operates with the new
parameter value after the controller is
enabled again
None
Display parameter
Change is not possible
2 Active level
Display
Meaning
Explanation
Menu
Menu level is active
Select main menu and submenus
Code
Code level is active
Select codes and subcodes
Para
Parameter level is active
Change parameters in the codes or
subcodes
None
Operating level is active
Display operating parameters
3 Short text
Display
Meaning
Explanation
alpha−
numerical
Contents of the menus, meaning of the codes
and parameters
In the operating level display of C0004 in % and
the active fault