Function library – Lenze E82xVxxxKxxxxx User Manual
Page 426

Function library
Code table
l
426
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0421
*
v
(Cont.)
Possible analog signals for C0421
^ 338
0
Output frequency
(MCTRL1−NOUT+SLIP)
24000
º 480 Hz
1
Device utilisation (MCTRL1−MOUT) at
V/f characteristic control (C0014 = 2 or
3)
16383
º Rated active inverter
current (active current/C0091)
Actual motor torque (MCTRL1−MACT)
with vector control (C0014 = 4) or
sensorless torque control (C0014 = 5)
16383
º Rated motor torque
2
Apparent motor current
(MCTRL1−IMOT)
16383
º Rated inverter current
3
DC−bus voltage (MCTRL1−DCVOLT)
16383
º 565 V DC at 400 V mains
16383
º 325 V DC at 230 V mains
4
Motor power
285
º Rated motor power
5
Motor voltage (MCTRL1−VOLT)
16383
º Rated motor voltage
6
1/output frequency (1/C0050)
(MCTRL1−1/NOUT)
195
º 0.5 ´ C0011
7
Output frequency within adjusted
limits (DCTRL1−C0010...C0011)
24000
º 480 Hz
0 5 f t C0010
24000 @ (f * C0010)
480 Hz
5 f w C0010
8
Operation with process controller
(C0238 = 0, 1):
Actual process controller value
(PCTRL1−ACT)
24000
º 480 Hz
Operation without process controller
(C0238 = 2):
Output frequency without slip
(MCTRL1−NOUT)