Function library – Lenze E82xVxxxKxxxxx User Manual
Page 265

Function library
Operating mode
Sensorless torque control with speed limitation
l
265
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0077
*
Gain of the
I
max
controller
0.25
0.00
= P component
inactive
{0.01}
16.00
^ 327
C0078
*
Reset time of
the I
max
controller
65
à
13
0
12
{1 ms}
9990
= I component
inactive
à
Only 8200 vector 15 ... 90 kW)
^ 327
C0087 Rated motor
speed
à
300
{1 rpm}
16000
à
Device−dependent
^ 315
C0088 Rated motor
current
à
0.0
0.1 (A)
650.0
à
Device−dependent
0.0 ... 2.0 x rated output current of
the controller
^ 315
C0089 Rated motor
frequency
50
10
{1 Hz}
960
^ 315
C0090 Rated motor
voltage
à
50
{1 V}
500
à
230 V for 230 V controllers,
400 V for 400 V controllers
^ 315
C0091 Motor cos
ϕ
а
0.40
{0.1}
1.0
а
Device−dependent
^ 315
C0092 Motor stator
inductance
0.0
0.000
{0.1 mH}
Device−dependent
^ 315
0.00
0.00
{0.01
mH}
Device−dependent Only 8200 vector 15 ... 90 kW
C0148
*
s
Identifying
motor data
0
0
Ready
Only when the motor is cold!
1. Inhibit controller, wait until
drive is at standstill
2. Enter the correct values from
the motor nameplate in C0087,
C0088, C0089, C0090, C0091
3. Set C0148 = 1, confirm with
v
4. Enable controller:
The identification
– starts,
c goes out
– the motor "whistles" faintly
but it does not rotate!
– takes approx. 30 s
– is completed when
c is lit
again
5. Inhibit controller
^ 315
1
Start identification
l
V/f rated frequency (C0015), slip
compensation (C0021) and motor
stator inductance (C0092) are
calculated and saved
l
The motor stator resistance (C0084)
= total resistance of the motor cable
and motor is measured and saved
Setting of torque control
Use C0014 = 5 to set the operating mode "sensorless torque control".
Linking setpoint and selecting speed limitation
Link an external setpoint source with the torque setpoint via C0412/6. (
¶ 328)
Select the type of speed limitation. The speed is limited via setpoint 1 or the maximum
frequency:
ƒ
Setpoint 1, if C0412/1 is linked with a setpoint source.
ƒ
Maximum frequency, if C0412/1 is not assigned.