Function library, Code table – Lenze E82xVxxxKxxxxx User Manual
Page 383

Function library
Code table
l
383
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0007
v
uSEr
Fixed
configuration
digital inputs
Change of C0007 is copied into
the corresponding subcode of
C0410. Free configuration in
C0410 sets C0007 = 255!
^ 343
0
E4
E3
E2
E1
l
CW/CCW = clockwise
rotation/counter−clockwise
rotation
l
DCB = DC injection brake
l
QSP = quickstop
l
PAR = change over parameter
set (PAR1
ó PAR2)
– PAR1 = LOW, PAR2 = HIGH
– The terminal in PAR1 and
PAR2 has to be assigned with
the "PAR" function.
– Only use configurations with
"PAR" if C0988 = 0
l
TRIP−Set = external error
0
CW/CCW
DCB
JOG2/3
JOG1/3
1
CW/CCW
PAR
JOG2/3
JOG1/3
2
CW/CCW
QSP
JOG2/3
JOG1/3
3
CW/CCW
PAR
DCB
JOG1/3
4
CW/CCW
QSP
PAR
JOG1/3
5
CW/CCW
DCB
TRIP−Set
JOG1/3
6
CW/CCW
PAR
TRIP−Set
JOG1/3
7
CW/CCW
PAR
DCB
TRIP−Set
8
CW/CCW
QSP
PAR
TRIP−Set
9
CW/CCW
QSP
TRIP−Set
JOG1/3
10
CW/CCW
TRIP−Set
UP
DOWN
C0007
v
uSEr
(Cont.)
E4
E3
E2
E1
l
Selection of fixed
setpoints
JOG1/3
JOG2/3
LOW LOW
HIGH LOW
LOW HIGH
HIGH HIGH
Active
C0046
JOG1
JOG2
JOG3
11
CW/CCW
DCB
UP
DOWN
12
CW/CCW
PAR
UP
DOWN
13
CW/CCW
QSP
UP
DOWN
14
CCW/QSP
CW/QSP
DCB
JOG1/3
15
CCW/QSP
CW/QSP
PAR
JOG1/3
16
CCW/QSP
CW/QSP
JOG2/3
JOG1/3
17
CCW/QSP
CW/QSP
PAR
DCB
18
CCW/QSP
CW/QSP
PAR
TRIP−Set
19
CCW/QSP
CW/QSP
DCB
TRIP−Set
C0007
v
uSEr
(Cont.)
E4
E3
E2
E1
l
UP/DOWN = motor
potentiometer functions
l
H/Re = manual/remote
change−over
l
PCTRL1−I−OFF = switch off I
component of process
controller
l
DFIN1−ON = digital frequency
input 0 ... 10 kHz
l
PCTRL1−OFF = switch off
process controller
20
CCW/QSP
CW/QSP
TRIP−Set
JOG1/3
21
CCW/QSP
CW/QSP
UP
DOWN
22
CCW/QSP
CW/QSP
UP
JOG1/3
23
H/Re
CW/CCW
UP
DOWN
24
H/Re
PAR
UP
DOWN
25
H/Re
DCB
UP
DOWN
26
H/Re
JOG1/3
UP
DOWN
27
H/Re
TRIP−Set
UP
DOWN
28
JOG2/3
JOG1/3
PCTRL1−I−O
FF
DFIN1−ON
29
JOG2/3
DCB
PCTRL1−I−O
FF
DFIN1−ON
30
JOG2/3
QSP
PCTRL1−I−O
FF
DFIN1−ON