Function library, Code table – Lenze E82xVxxxKxxxxx User Manual
Page 392

Function library
Code table
l
392
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0111
v
Configuration
of analog
output X3/62
(AOUT1−IN)
Output of analog signals to terminal
Change of C0111 is copied into
C0419/1. Free configuration in
C0419/1 sets C0111 = −255−!
^ 332
0
0
Output frequency with slip
(MCTRL1−NOUT+SLIP)
6 V/12 mA
º C0011
1
Device utilisation (MCTRL1−MOUT) at
V/f characteristic control (C0014 = 2 or
3)
3 V/6 mA
º rated active inverter
current (active current/C0091)
Actual motor torque (MCTRL1−MACT)
with vector control (C0014 = 4) or
sensorless torque control (C0014 = 5)
3 V/6 mA
º rated motor torque
2
Apparent motor current
(MCTRL1−IMOT)
3 V/6 mA
º rated inverter current
3
DC−bus voltage (MCTRL1−DCVOLT)
6 V/12 mA
º DC 1000 V (400 V
mains)
6 V/12 mA
º DC 380 V (240 V
mains)
4
Motor power
3 V/6 mA
º rated motor power
5
Motor voltage (MCTRL1−VOLT)
4.8 V/9.6 mA
º rated motor
voltage
6
1/output frequency (1/C0050)
(MCTRL1−1/NOUT)
2 V/4 mA
º 0.5 ´ C0011
7
Output frequency within adjusted
limits (DCTRL1−C0010...C0011)
0 V/0 mA/4 mA
º f = f
min
(C0010)
6 V/12 mA
º f = f
max
(C0011)
8
Operation with process controller
(C0238= 0, 1):
Actual process controller value
(PCTRL1−ACT)
6 V/12 mA
º C0011
Operation without process controller
(C0238 = 2):
Output frequency without slip
(MCTRL1−NOUT)
9
Ready for operation (DCTRL1−RDY)
Selection 9 ... 25 corresponds to
the digital functions of the relay
output K1 or the digital switching
output K1 (C0008) or the digital
output A1 (C0117):
LOW = 0 V/0 mA/4 mA
HIGH = 10 V/20 mA
10
TRIP error message (DCTRL1−TRIP)
11
Motor is running (DCTRL1−RUN)
12
Motor is running / CW rotation
(DCTRL1−RUN−CW)
13
Motor is running / CCW rotation
(DCTRL1−RUN−CCW)
14
Output frequency = 0
(DCTRL1−NOUT=0)
15
Frequency setpoint reached
(MCTRL1−RFG1=NOUT)
16
Values have fallen below frequency
threshold Q
min
(f < C0017)
(PCTRL1−QMIN)
LOW active
17
I
max
limit reached (MCTRL1−IMAX)
C0014 = −5−: Torque setpoint reached
18
Overtemperature (
ϑ
max
− 5 °C)
(DCTRL1-OH-WARN)
19
Values have fallen below TRIP or Q
min
or pulse inhibit (IMP) is active
(DCTRL1−TRIP−QMIN−IMP)
20
PTC warning (DCTRL1−PTC−WARN)