Function library, Limit value setting speed range, Codes for parameter setting – Lenze E82xVxxxKxxxxx User Manual
Page 282

Function library
Limit value setting
Speed range
l
282
EDS82EV903 EN 3.0
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0010
uSEr
Minimum
output
frequency
0.00
0.00
à
14.5 Hz
{0.02
Hz}
650.00
l
C0010 not effective in the case
of bipolar setpoint selection
(−10 V ... + 10 V)
l
C0010 only limits the analog
input 1
l
In the case of a max. output
frequency > 50 Hz the
switching threshold of the auto
DCB in C0019 has to be
increased.
l
From software 3.5: If
C0010 > C0011, the drive does
not start when controller
enable is set.
à
Speed setting range 1 : 6 for
Lenze geared motors: For
operation with Lenze geared
motors has to be set
necessarily.
^ 281
C0011
uSEr
Maximum
output
frequency
50.00 7.50
à
87 Hz
{0.02
Hz}
650.00
C0239 Lower
frequency
limitation
−650.0
0
−650.00
{0.02
Hz}
650.00
l
The value does not fall below
the limit independently of the
setpoint
l
If the lower frequency
limitation is active, automatic
DC injection braking (auto DCB)
must be deactivated with
C0019 = 0 or C0106 = 0
^ 281
C0236
(A)
Acceleration
time − lower
frequency
limitation
0.00
0.00
{0.02 s}
1300.00 Based on C0011
Lower frequency limitation =
C0239
^ 281
Adjustment
Relationship between output frequency and synchronous motor speed:
n
rsyn
+ C0011 @ 60
p
n
rsyn
Synchronous motor speed [rpm]
C0011
Max. output frequency [Hz]
p
Number of pole pairs (1, 2, 3, ...)
Example:
4−pole asynchronous motor: p = 2, C0011 = 50 Hz
n
rsyn
+ 50 @ 60
2
+ 1500 min
*1