Extensions for automation – Lenze E82xVxxxKxxxxx User Manual
Page 168

Extensions for automation
Standard devices in a power range from 0.25 ... 2.2 kW
Mounting and dismounting function modules
l
168
EDS82EV903 EN 3.0
Mounting
8200vec601
Fig. 7−1
Worksteps
1. Disconnect the drive controller from mains and wait at least 3 minutes!
2. Remove the FIF cover
0 from the FIF interface.
3. Remove protective cap
1 of the function module 2 and plug function module onto
the FIF interface.
4. Insert the plug connector
3 into the contact strip of the function module until it
snaps in.
Additionally fit the retaining clip so that the module cannot be removed together with the
terminal strips
5 during wiring:
5. Insert the retaining clip
4 into the recess, place it on the function module and latch
it.
6. Wire the function module (see mounting instructions of the function module).
)
Note!
Keep the FIF cover
0 and the protection cover of the function module 1 so that
you can attach them again after you have dismounted the function module.
The controller can only be commissioned if a function module or the FIF cover
0 is plugged on the FIF interface.