6 activating password protection, Activating password protection, Parameter setting – Lenze E82xVxxxKxxxxx User Manual
Page 242

Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Activating password protection
l
242
EDS82EV903 EN 3.0
9.3.6
Activating password protection
)
Note!
ƒ
If the password protection is activated (C0094 = 1 ... 9999), you have only
free access to the user menu.
ƒ
Before you can access the other menus, you must enter the password.
ƒ
Please observe that the password−protected parameters can be overwritten
as well when transferring the parameter sets to other standard devices. The
password is also transferred.
ƒ
Do not forget your password! If you have forgotten your password, it can
only be reset via a PC or a bus system!
Activate password protection
Step
Key seq.
Action
1.
Select submenu 2.1, "ALL", from the
"Code list" in menu 2
z y Z Y
Change to the "ALL" user menu using the arrow keys
2.
Change to the code level
Z
Display of code C0001 "Setpt setup"
3.
Select C0094
z
Display of code C0094 "User password"
4.
Change to the parameter level
V
Display "0" (no password protection)
5.
Set password
A
z
Select password (1 ... 9999)
B
T V
Confirm password
6.
Change to the code level
A
V
Display of the operating level
B
V
Display of C0094 and "User password"
7.
Change to menu 1, "USER menu"
Y Y y
The password protection is active now:
l
"Enter password" is displayed every time you want to quit the user menu.
l
If you enter the correct password and confirm with
T V
, all menus can be accessed freely again.