4 functional test, 1 important notes, Important notes – Lenze E82xVxxxKxxxxx User Manual
Page 498

Safety engineering
Functional test
Important notes
l
498
EDS82EV903 EN 3.0
14.4
Functional test
14.4.1
Important notes
}
Danger!
Unexpected start−up of the machine possible
The "Safe torque off" safety function provides protection against an
unexpected start−up of the drive and therefore is an important item within the
safety concept for a machine. It has to be ensured that this function works
correctly.
Possible consequences:
ƒ
Death, severe injury, or damage to material assets, when the safety function
fails.
Protective measures:
After the installation and at regular intervals, the operator has to check the
function of the "Safe torque off" circuit.
ƒ
When doing this, check both disconnecting paths separately with regard to
their disconnection capability.
ƒ
The functional test can be carried out manually or automatically via the PLC.
ƒ
Basically the inspection interval depends on the application and the
corresponding risk analysis, as well as on the system as a whole. It should
not exceed 1 year.
ƒ
If the functional test shows impermissible states,
– the drive or the machine has to be shut down immediately.
– commissioning is not permitted until the safety function operates
correctly.