IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0015
uSEr
V/f rated
frequency
50.00 7.50
{0.02
Hz}
960.00
l
C0015 is calculated and saved
during the motor parameter
identification with C0148.
l
The setting applies to all
permitted mains voltages
^ 257
^ 261
C0016
uSEr
V
min
boost
а
0.00
{0.01 %}
40.00
а
device−dependent
Setting applies to all permitted
mains voltages
^ 257
Set V/f characteristic
Select the V/f characteristic suitable for your application in C0014.
)
Note!
Please observe the following if you operate drives with quadratic V/f
characteristics:
ƒ
Great moments of inertia reduce the acceleration of the drive.
ƒ
This drive behaviour can be avoided if the linear V/f characteristic is used via
parameter set changeover during acceleration.
Set V/f rated frequency
The V/f rated frequency determines the lead of the V/f characteristic and is a crucial factor
for the motor behaviour in terms of current, torque and power.
ƒ
The setting in C0015 applies to all permissible mains voltages.
ƒ
The internal mains voltage compensation compensates for fluctuations in mains
voltage during operation so that these need not be considered when setting C0015.
ƒ
Depending on the setting in C0015, the maximum output frequency (C0011) may
have to be adapted to be able to cover the entire speed range.
ƒ
The V/f rated frequency depends on the rated controller voltage, the rated motor
voltage and the rated motor frequency:
C0015 [Hz] + U [V]
U
r
[V] @ f
r
[Hz]
U
400 V for E82xVxxxK4C types
U
230 V for E82xVxxxK2C types
V
r
Rated motor voltage depending on the connection method
according to nameplate data
f
r
Rated motor frequency according to nameplate data
)
Note!
C0015 is calculated during motor parameter identification. The value is saved
automatically.