12 free interconnection of digital signals, 1 free configuration of digital input signals, Function library – Lenze E82xVxxxKxxxxx User Manual
Page 343

Function library
Free interconnection of digital signals
Free configuration of digital input signals
l
343
EDS82EV903 EN 3.0
10.12
Free interconnection of digital signals
10.12.1
Free configuration of digital input signals
Description
ƒ
Internal digital signals can be freely assigned to external digital signal sources. It is
thus possible to achieve a freely configured control of the controller
– Digital inputs X3/E1 ... X3/E6
– Digital process data input words
ƒ
A signal source can be assigned to several targets. Please ensure reasonable
assignments. Otherwise it is possible to activate functions which cannot be
operated together (e.g. a digital signal linked with quick stop and DC braking at the
same time).
)
Note!
Use C0007 to configure some internal digital signals with the digital inputs
X3/E1 ... X3/E4 block by block. The corresponding subcodes of C0410 will be
adapted automatically.
)
Note!
The default setting defines the signals for the most frequently used function
modules of the standard I/O and application I/O. If the default setting is
changed, all unused signals must be set to FIXED−FREE in order to ensure
trouble−free operation.
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0410
v
Free
configuration
of digital input
signals
Linking of digital signal sources to internal
digital signals
A selection in C0007 is copied to
the corresponding subcode of
C0410. A change in C0410 sets
C0007 = 255!
^ 343
1 NSET1−JOG1/3
NSET1−JOG1/3
/5/7 (A)
1
Digital input X3/E1
Selection of fixed
setpoints
C0410/1
C0410/
2
C0410/33
LOW LOW LOW
HIGH LOW LOW
LOW HIGH LOW
...
...
...
HIGH HIGH HIGH
Active
C0046
JOG1
JOG2
...
JOG7
2 NSET1−JOG2/3
NSET1−JOG2/3
/6/7 (A)
2
Digital input X3/E2
3 DCTRL1−CW/
CCW
4
Digital input X3/E4
CW = clockwise
rotation
CCW =
counter−clockwise
rotation
LOW
HIGH
4 DCTRL1−QSP
255
Not assigned (FIXED−FREE)
Quick stop (via terminal
LOW−active)
5 NSET1−RFG1−
STOP
255
Not assigned (FIXED−FREE)
Stop main setpoint of ramp
function generator