5 lateral mounting, Lateral mounting, Mechanical installation – Lenze E82xVxxxKxxxxx User Manual
Page 70

Mechanical installation
Standard devices in a power range from 0.25 ... 2.2 kW
Lateral mounting
l
70
EDS82EV903−3.0
5.2.5
Lateral mounting
For this mounting variant you require the controller type E82EV...
)
Note!
This mounting variant does not enable a CE−typical drive system to be
installed.
Lateral mounting of the controller is possible on both sides. The controller is either fixed
or can be swivelled depending on the mounting point. Both mounting types use the same
mounting kit.
Fixed lateral mounting
ƒ
The fixing rails included in the scope of supply can be used for controllers 0.25 ...
0.75 kW.
ƒ
A mounting set is required for controllers 1.5 ... 2.2 kW:
– Order number E82ZJ001 for 8200 vector 1.5 ... 2.2 kW
8200vec074
Fig. 5−8
Fixed lateral mounting
Bolt here
8200 vector
Mounting kit
Dimensions [mm]
a
b
b
1
b
2
c
1)
d
e
E82EV251K2C
E82EV371K2C
−
Use the fixing rails included in the scope of supply for fixed installation to
the sides. Dimensions:
^ 62
E82EV551KxC
E82EV751KxC
E82EV152KxC
E82EV222KxC
E82ZJ001
60
306
280 ... 295
240
162
6.5
39
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 14 mm.