Function library – Lenze E82xVxxxKxxxxx User Manual
Page 423

Function library
Code table
l
423
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0419
v
(Cont.)
Possible analog signals for C0419
Selection 9 ... 25 corresponds to
the digital functions of the relay
output K1 or the digital switching
output K1 (C0008) or the digital
output A1 (C0117):
LOW = 0 V/0 mA/4 mA/ 0 kHz
HIGH =
10 V/20 mA/10 kHz
^ 332
9
Ready for operation (DCTRL1−RDY)
10
TRIP error message (DCTRL1−TRIP)
11
Motor is running (DCTRL1−RUN)
12
Motor is running / CW rotation
(DCTRL1−RUN−CW)
13
Motor is running / CCW rotation
(DCTRL1−RUN−CCW)
14
Output frequency = 0
(DCTRL1−NOUT=0)
15
Frequency setpoint reached
(DCTRL1−RFG1=NOUT)
16
Values have fallen below frequency
threshold Q
min
(f < C0017)
(PCTRL1−QMIN)
LOW active
17
I
max
limit reached (MCTRL1−IMAX)
C0014 = −5−: Torque setpoint reached
18
Overtemperature (
J
max
− 5 °C)
(DCTRL1-OH-WARN)
19
TRIP or Q
min
or pulse inhibit (IMP)
active (DCTRL1−TRIP−QMIN−IMP)
20
PTC warning (DCTRL1−PTC−WARN)
21
Apparent motor current < current V−belt monitoring min = C0017 22 Apparent motor current < current min (DCTRL1−(IMOT 23 Apparent motor current < current 24 Motor phase failure warning 25 Min. output frequency reached £ C0010) (PCTRL1−NMIN) LOW active
threshold (DCTRL1−IMOT
Apparent motor current = C0054
Current threshold = C0156
Frequency threshold Q
threshold and output frequency >
Frequency threshold Q
threshold and ramp function generator
1: input = output
(DCTRL1−(IMOT
(DCTRL1−LP1−WARN)
(f