Technical data – Lenze E82xVxxxKxxxxx User Manual
Page 40

Technical data
Operation with rated power (normal operation)
Rated data for 400 V mains voltage
l
40
EDS82EV903 EN 3.0
Typical motor power
Three−phase asynchronous
motor (4−pole)
P
rated
[kW]
7.5
11
P
rated
[hp]
10.0
15
8200 vector type
EMC filter integrated
E82xV752K4C0xx
E82xV113K4C0xx
3)
Without EMC filter
E82xV752K4C4xx
E82xV113K4C2xx
3)
Rated mains current at a
switching frequency of 8 kHz
(Lenze setting)
without mains choke
I
mains
[A]
21.5
−
with mains choke
I
mains
[A]
15.0
21.0
Output power +U
DC
, −U
DC
1)
P
DCres
[kW]
1.5
0
Rated output
current at
switching
frequency
2 kHz sin
I
r
[A]
16.5
23.5
4 kHz sin
8 kHz sin
I
r
[A]
16.5
23.5
16 kHz sin
2)
I
r
[A]
10.7
13.0
Max. permissible
output current for
60 s at switching
frequency
2 kHz sin
I
max
[A]
24.8
35.3
4 kHz sin
8 kHz sin
I
max
[A]
24.8
35.3
16 kHz sin
2)
I
max
[A]
16.0
19.5
Power loss (operation with I
N8
)
E82EV...
P
loss
[W]
300
410
E82DV... inside/outside
P
loss
[W]
100/200
137/273
E82CV... inside/cooler
P
loss
[W]
100/200
137/273
Dimensions
Dependent on the mounting variant (
^ 61)
Mass
E82EV...
m [kg]
3.6
E82DV...
m [kg]
3.6
E82CV...
m [kg]
3.0
1)
Power supplied by the DC bus when operating with power−adapted motor
2)
Switching frequency is reduced to 4 kHz if
J reaches max. − 5 °C
3)
Operation only permitted with mains choke (
^ 106)