Function library – Lenze E82xVxxxKxxxxx User Manual
Page 395

Function library
Code table
l
395
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0135
*
Drive controller
control word
(parameter
channel)
Bit
Assignment
l
Control of drive controller via
parameter channel. The most
important control commands
are summarised in bit
commands
l
C0135 cannot be changed
using the keypad
1|0
JOG1, JOG2, JOG3 or C0046
(NSET1−JOG1/3, NSET1−JOG2/3)
00
01
10
11
C0046 active
JOG1 (C0037) active
JOG2 (C0038) active
JOG3 (C0039) active
2
0
1
Current direction of rotation
(DCTRL1−CW/CCW)
Not inverse
Inverse
3
0
1
Quick stop (DCTRL1−QSP)
Not active
Active
4
0
1
Stop ramp function generator
(NSET1−RFG1−STOP)
Not active
Active
5
0
1
Ramp function generator input = 0
(NSET1−RFG1−0)
Not active
Active (deceleration at C0013)
RFG1 = ramp−function generator
main setpoint
6
0
1
UP function motor potentiometer
(MPOT1−UP)
Not active
Active
7
0
1
DOWN function motor potentiometer
(MPOT1−DOWN)
Not active
Active
8
reserved
9
0
1
Controller inhibit (DCTRL1−CINH)
Controller released
Controller inhibited
10
TRIP set (DCTRL1−TRIP−SET)
Sets "external error" fault in the
drive controller (EEr , LECOM no.
91)
11
0
Þ 1
TRIP reset (DCTRL1−TRIP−RESET)
Edge causes TRIP reset
13|12
Change over parameter sets
(DCTRL1−PAR2/4, DCTRL1−PAR3/4)
00
01
10
11
PAR1
PAR2
PAR3
PAR4
14
0
1
DC injection brake (MTCRL1−DCB)
Not active
Active
15
Reserved