Function library – Lenze E82xVxxxKxxxxx User Manual
Page 369

Function library
Parameter set management
Saving and copying parameter sets
l
369
EDS82EV903 EN 3.0
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0002
*
s
uSEr
(Cont.)
Transferring
parameter sets
with the
keypad
Keypad
ð PAR1 (+ FPAR1)
Overwrite selected parameter set
and, if required FPAR1, with the
corresponding data of the keypad
71
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
11
with all other function modules
Keypad
ð PAR2 (+ FPAR1)
72
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
12
with all other function modules
Keypad
ð PAR3 (+ FPAR1)
73
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
13
with all other function modules
Keypad
ð PAR4 (+ FPAR1)
74
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
14
with all other function modules
Controller
ð keypad
Copy all available parameter sets
(PAR1 ... PAR4, if required FPAR1)
into the keypad
80
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
20
with all other function modules
Keypad
ð function module
Only overwrite the
module−specific parameter set
FPAR1 with the data of the keypad
40
only with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
Function module
ð keypad
Only copy the module−specific
parameter set FPAR1 into the
keypad
50
only with function module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet/CANopen
C0002
*
s
uSEr
(Cont.)
Saving your
own basic
setting
9
PAR1
ð own basic setting
For the parameters of the
controller you can save an own
basic setting (e.g. the delivery
status of your machine):
1. Ensure that parameter set 1 is
active
2. Inhibit controller
3. Set C0003 = 3, confirm with
v
4. Set C0002 = 9, confirm with
v, the own basic setting is
saved
5. Set C0003 = 1, confirm with
v
6. Enable the controller
C0002
*
s
uSEr
(Cont.)
Loading/copyin
g the own basic
setting
By using this function you can also
just copy PAR1 into the parameter
sets PAR2 ... PAR4
5
own basic setting
ð PAR1
Restore own basic setting in the
parameter set selected
6
own basic setting
ð PAR2
7
own basic setting
ð PAR3
8
own basic setting
ð PAR4