beautypg.com

Snmp-server informs – Avaya P330-ML-ML User Manual

Page 218

background image

Chapter 2 Avaya P330-ML Layer 2 CLI Commands

204

Avaya P330-ML Reference Guide

Example:

snmp-server informs

User level: supervisor
Use the snmp-server informs command to configure inform parameters.

udp-port
(Optional)

Keyword that specifies that a specific UDP port on the target
host should be used when sending notifications to the host.
The default UDP port is 162.

port

The UDP port on the target host to which notifications are sent.

notification

-type-list
(Optional)

List of notification types. Each types combines related
notifications. You can enable or disable notification generations
on a per group basis. For example, the swRedundancy type
groups new and delete software redundancy notifications.
If no notification-type-list is specified, the default, all, is used.
• all/* – All traps
• generic – Generic traps
• config – Config change notifications
• eth-port-faults – Ethernet port fault notifications
• sw-redundancy – Software redundancy notifications
• temperature – Temperature warning notifications
• cam-change – Changes in CAM notifications
• l3-faults – Layer 3 faults, including duplicate IP and

VLAN violations

• lag-event – Link aggregation faults and configuration

changes

• policy – Changes in policy notifications (for L3 devices)
• link-down-faults – ITC proprietary link down

notifications

• supply – Power supply notifications (main and backup)
• fan – FAN faults notifications (main and backup)
• cascade – Cascade connection fault notifications.
Note that the list of notification names is proprietary to ITC.

P330-N>snmp-server host 149.49.38.221 informs v3 noauth

charlieBrown

Done!