Chapter 2 Avaya P330-ML Layer 2 CLI Commands

Avaya P330-ML Reference Guide

171

Example:

Example:

show powerinline image version

User level: user, privileged, supervisor
L This command applies to P333T-PWR switches only and is used by P330-

ML-ML switches to control P333T-PWR modules in the stack.

Use the show powerinline image version command to display the current

P330-ML-2> show powerinline 3

External power Supply is 400Watts.

External power supply is active.

Port

Inline

Operational

Status

Power

Allocated

Class

Powering

Priority

----

-----------

---------

--------

3/1

on

0

Low

3/2

on

0

Low

3/3

on

0

High

3/4

off

0

High

...

P330-ML-2> show powerinline 2/1

External power Supply is 400Watts.

External power supply is active.

Port

Inline

Operational

Status

Power

Allocated

Class

Powering

Priority

----

-----------

---------

--------

2/1

off

0

Low