Using the sequence function – GW Instek PSB-2000 Series User Manual User Manual
Page 85

OPERATION
85
Using the Sequence Function
Description
The section ―Sequence Function‖ (page 60) shows
how to execute a sequence program on the power
supply when equipped with the optional interface
board. The PSB_Sequence_203 software is used to
create a program in advance via the optional
interface board. See the Sequence Function section
on page 60 for details. The PSB_Sequence_203
software can be downloaded at the GW Instek
website.
Procedure
1. Write a sequence program through the
interface board. See page 60
2. Activate the sequence function as shown in the
Sequence Function menu on page 60.
3. Execute the sequence operation with the
PRESET key(s).
Each PRESET key has two functions. The
function of the PRESET keys and the OUTPUT
key are different when used in the sequence
mode compared to when they are in the
normal operating mode.
Below is a description of the function of each
of the preset keys and the OUTPUT key when
in the sequence mode.
Normal Mode
Sequence Mode
PRESET 1
Starts or pauses the sequence
program. (
)
PRESET 2
Skips to the previous step number.
( ) (when paused)
PRESET3
Skips to the next step number in
the sequence. ( ) (when paused)