EXTERNAL CONTROL

131

Remote/Local Setting (:REMOTE)

This command sets or inquires about the remote/local status.

Setting

:REMOTE

is as shown below:
0: Local status (Normal manual operation)
1: Remote status
2: Local lockout remote status (Cannot return to the local
status through key operation.)

Application
example

:REMOTE0
Sets the unit to local status.

Query

:REMOTE?

Response
example

1
Indicates that the unit is in the remote status. The query
return value has the same meaning as the setting .

Remark

If this query is sent when the unit is in the local status, a
response is made after the unit enters the remote status.