PSB-2000 Series User Manual

36

Fig. Parts to be
cut

Connection with the Rear Output Terminals (PSB-2400H,
2800H)

Procedure

1. Remove the AC cable from the AC INPUT.

2. Insert the load line and then use a flathead

screwdriver or similar tool to firmly secure it.

3. If necessary, use the supplied output ground

cable and screw to establish a positive or
negative ground connection to the output
ground terminal ( mark).

CAUTION

Noise at the load end may be reduced by twisting
the cables to the load or connecting a film
capacitor (low impedance, high-frequency, several
μF) and an electrolytic capacitor (several hundred
μF) to the load end.