Off timer on/off (:timer:mod), Off timer value setting (:timer:set) – GW Instek PSB-2000 Series User Manual User Manual

Page 122

background image

PSB-2000 Series User Manual

122

Response
example

1
Indicates that output On/Off with external contacts is
working. The query return value has the same meaning
as the setting .

Remark

This command causes an error if the sequence function is
running.

Off Timer ON/OFF (:TIMER:MOD)

This command activates or deactivates the Off Timer.

Setting

:TIMER:MOD
is as shown below:
0: Deactivates the Off Timer.
1: Activates the Off Timer.

Application
example

:TIMER:MOD 1
Activates the Off Timer.

Query

:TIMER:MOD?
Inquires about the setting.

Response
example

1
Indicates that the Off Timer is activated. The query return
value has the same meaning as the setting .

Remark

This command causes an error if the sequence function is
running.

Off Timer Value Setting (:TIMER:SET)

This command sets or inquires what the value of the Off Timer
setting is.

Setting

:TIMER:SET
The range is between 0.1 and 99.5. Specify the
hour in the integer part and the minutes in the first
decimal place (in units of 10 minutes).

Application
example

:TIMER:SET 10.3
Set the Off Timer value to 10 hours and 30 minutes.

Query

:TIMER:SET?
Inquires about the setting.

Response
example

15.2
Indicates that the Off Timer value is set to 15 hours and
20 minutes.

Remark

This command causes an error if the sequence function is
running.
It also causes an error if a value between 6 and 9 is set in
the first decimal place (I.e, a value of greater the 60
minutes).