58

Off Timer Function

Menu Item: 04(PSB-L Series), 03(PSB-H Series)

Introduction

This function turns the output off automatically after
a set amount of time. The timer can be set in ten
minute steps to a maximum of 99 hours, 50 minutes.

Procedure

1. Press the MENU key until menu number ―04‖ is

displayed(PSB-L) or ―03(PSB-H series)

2. Press the ENTER /

CHECK

key to enter the Off

Timer settings.

3. Select ON or OFF with the encoder wheel. The

Off Timer is turned off by default.

Initial setting

OFF timer activated

4. Press the ENTER /

CHECK

key to confirm the

setting.
The OFF TIMER LED in the center of the panel
will turn on when the timer is active.

OFF TIMER

DELAY

Hi-Ω

5. Next, set the timer time with the encoder

wheel.
Press the ENTER /

CHECK

key to confirm the

setting.