beautypg.com

GW Instek PSB-2000 Series User Manual User Manual

Page 105

background image

EXTERNAL CONTROL

105

Procedure

1. Turn on the unit while holding the A key to

set the System Address and/or Personal
Computer Address. The model name and
version data are displayed first, and then the
interface type is displayed. After this, the
System Address may be set

1

. ―Sy.Ad‖ is

displayed on the Voltage LED, and the
address is displayed on the Current LED.
Rotate the encoder to select the System
Address, and press the ENTER /

CHECK

key to

confirm.

A unit whose System Address is set other than
1 will return to normal operation.

1

Keep the A key depressed until ―Sy.Ad‖ is

displayed.

System Address 1

2. If the System Address is set to 1, ―PC.Ad‖ is

displayed on the Voltage LED, indicating that
a Personal Computer Address can be set.
Rotate the encoder to select the Personal
Computer Address, and press the ENTER /

CHECK

key to confirm.


The unit will return to normal operation.

Personal Computer Address 4