beautypg.com

External control setting (:ext:mod) – GW Instek PSB-2000 Series User Manual User Manual

Page 119

background image

EXTERNAL CONTROL

119

External Control Setting (:EXT:MOD)

This command sets the external control mode.

Setting

:EXT:MOD
is as shown below:
0: Settings are controlled from the front panel or via
remote control.
1: External voltage control
2: External resistance control

Application
example

:EXT:MOD 1
Selects the external voltage control.

Query

:EXT:MOD?
Inquires about the setting status.

Response
example

1
Indicates that external voltage control has been enabled.
The query return has the same meaning as the setting
.

Remark

This command causes an error if a sequence operation is
running.

External Control of the Voltage Output ON/OFF
(:EXT:VOLT)

This command chooses whether the external control is used to
control the output voltage or if the front panel controls are used to
control the output voltage.

Setting

:EXT:VOLT
Activates or deactivates external control of the output
voltage of a single channel model.
:EXT:VOLT:A
Activates or deactivates external control of the output
voltage of CH1.
:EXT:VOLT:B
Activates or deactivates external control of the voltage
output of CH2.
is as shown below:
0: Deactivates external control of the voltage output
(Allows the voltage output to be controlled from the front
panel or from remote control).
1: Activates external control of the voltage output.

Application
example

:EXT:VOLT 1
Selects external control of the voltage output.

Query

:EXT:VOLT?