155
Sequence item: Power
410W/820W
O
Sequence item: Output
OFF
O
Sequence item: Time
1sec
O
Key lock function
OFF
×
One-control operation
OFF
O
Output status
Initialized when power is turned off. ×
Sequence operation status
×(Stop status)
×
Off-timer operation status
×(Non operating status)
×
System Address
1
O
Personal Computer Address 3
O
Parallel/Serial Operation Setting Table
PSB-2400H
Item
Single
Parallel
400H
400H x 2
400W
800W
Voltage Setting
SLOW
100mV
FAST
10V
Range
0V to 820V
Min. display digit 100mV
Current Setting
SLOW
10mA
100mA
FAST
1A
1A
Range
0A to 3.07A
0A to 6.1A
Min. display digit 10mA
Power Setting
SLOW
10W
20W
FAST
100W
200W
Range
10W to 410W
20W to 820W
Min. display digit 1W
OVP Setting
SLOW
1V
FAST
100V
Range
10V to 840V
Min. display digit 100mV
SLOW
10mA
20mA
FAST
1A
2A
Range
0.1A to 3.15A
0.2A to 6.3A
Min. display digit 10mA
10mA
For parallel connections, the smallest value that can be displayed (Min. display digit) for
current is 100mA. When some model combinations are used in parallel, the actual current
setting resolution may be different to the display resolution. In this situation the display
may not update with only one click of the encoder.