EXTERNAL CONTROL

113

OVP Setting (:VOLT:PROT)

This command sets or inquires about the OVP (over-voltage
protection) value.

Setting

:VOLT:PROT
Sets the OVP value of a single channel model.
:VOLT:PROT:A
Sets the OVP value of CH1.
:VOLT:PROT:B
Sets the OVP value of CH2.
The range is from 1.00 to 84.00(PSB-L), 10.0 to
840.0(PSB-H).
Two decimal places are valid.

Application
example

:VOLT: PROT 10.10
Sets the OVP value of a single channel model to 10.10V.

Query

:VOLT:PROT?
Inquires about the set OVP value of a single channel
model.
:VOLT:PROT:A?
Inquires about the set OVP value of CH1.
:VOLT:PROT:B?
Inquires about the set OVP value of CH2.

Response
example

10.10
Indicates that the set OVP value is 10.10V.

Remark

None

Output current setting (:CURR)

This command sets or inquires about the output current.

Setting

:CURR
Sets the output current of a single channel model.
:CURR:A
Sets the output current of CH1.
:CURR:B
Sets the output current of CH2.