beautypg.com

Sequence data transfer (:seq:download), Model inquiry (*idn?) – GW Instek PSB-2000 Series User Manual User Manual

Page 128

background image

PSB-2000 Series User Manual

128

Remark

None

Sequence Data Transfer (:SEQ:DOWNLOAD)

This command transfers the sequence set data.

Setting

:SEQ:DOWNLOAD
represents 1609-byte binary sequence set data.

Application
example

:SE:DOWNLOAD#6001600………… LF
Transfers an 8-byte header for the binary data, 1600-bytes
of actual data, and a 1 byte for the delimiter (total: 1609
bytes).

Query

:SEQ:DOWNLOAD?
Requests the sequence data.

Response
example

#6001600………… LF
1609-byte sequence set data are returned.

Remark

PSB_Sequence_203 software is available.
Use it for setting

1

1

The application software for sequence operation may be

downloaded from the GW Instek website.

Model Inquiry (*IDN?)

This command returns the company name, model name, serial
number and version number.

Setting

None.
Query only.

Query

*IDN?
The company name, model name, serial number and
version are returned in this order.

Response
example

GW Instek,PSB-2400L,0,1.00/1.00