EXTERNAL CONTROL

127

Sequence Start Step Setting (:SEQ:START)

This command specifies which step to start from when running a
sequence.

Setting

:SEQ:START

The range is from 0 to 99.

Application
example

:SEQ:START2
Sets the sequence to start from step no. 2.

Query

:SEQ:START?
Inquires about the setting.

Response
example

2
Indicates that the sequence starts from step 2.

Remark

None

Sequencer End Step Setting (:SEQ:END)

This command specifies which step to end the sequence on.

Setting

:SEQ:END
The range is from 0 to 99.

Application
example

:SEQ:END2
Sets the sequence to end at step no. 2.

Query

:SEQ:END?
Inquires about the setting.

Response
example

2
Indicates that the sequence ends at step no. 2.

Remark

None

Sequence Repetition Frequency Setting (:SEQ:CYCL)

This command specifies the number of times the sequence is
looped(repetition frequence).

Setting

:SEQ:YCL
The range is from 0 to 999.
When set to 0, the sequence is repeated endlessly (infinite
loops).

Application
example

:SEQ:CYCL 2
Sets the sequence to loop 2 times.

Query

:SEQ:CYCL?
Inquires about the setting.

Response
example

2
Indicates that the sequence is looped twice.