beautypg.com

Flexraybus trigger setup detail, Serial data debug solutions 80 – Teledyne LeCroy Serial Data Debug Solutions User Manual

Page 80

background image

Serial Data Debug Solutions

80

919586 RevA

FlexRaybus Trigger Setup Detail

The following topic provides specific control settings for a FlexRaybus Trigger.

All Trigger Setups use Source Setup, FlexRay Setup, and Trigger Type fields.

Other fields vary based on the Trigger Type Selections as follows:

TSS (Start) and FrameTriggers have

Setup Format

fields.

Frame Trigger has

Setup Format

,

Frame ID Setup

,

Cycle Count

, and

Frame Qualifier

fields.

Symbol Trigger has

Trigger On

and

System Parameters

fields.

Errors Trigger has

Protocol and CRC Errors

fields.

Previously numbered FlexRaybus trigger sections correspond with the following explanations.

1.

S

OURCES

S

ETUP

DATA - The pop-up dialog is used to select the appropriate channel or EXT input for each. Set this field up
with caution or your trigger may not function correctly.

Threshold (Trigger)High, Low, and Find - Adjust the vertical level thresholds for the trigger. FlexRay is a
tri-level signal and requires 2 voltage threshold settings which enable the oscilloscope to distinguish
between 1 and 0.

Like an Edge trigger, the level must be specified to process the incoming signals and determine if the
desired serial data pattern meets the set trigger condition.

If desired, use the automated Find Threshold button to detect and set appropriate thresholds.

2.

F

LEX

R

AY

S

ETUP

Bitrate - The FlexRay trigger can be configured to trigger on FlexRay signals at 2.5 Mb/s, 5 Mb/s and 10
Mb/s as defined in the FlexRay specification.

3.

T

RIGGER

T

YPE

The FlexRay trigger can be configured to trigger on simple TSS (Start), FlexRay Frame (ID, Cycle Count,
Frame Qualifiers)
, FlexRay Symbols (CID, CAS/MTS and Wakeup Pattern), and Error Frame triggering is
supported for FSS, BSS and FES, Header CRC and Payload CRC errors.

Select the Trigger Type desired. The trigger dialog dynamically changes based on the selection made in
the following manner:

TSS (Start) - When selected, the Setup Format fields are shown and enabled. However, the Frame ID
Setup, Cycle Count, and Frame Qualifiers fields, while shown, are disabled.