5. Table #Rows - Touch this option and provide a value (1-20) for the number of table rows for display. One

row of data is shown by default. If a value of 1 - 4 rows is provided, the scroll bar to the right of the table
is replaced with a pop-up scroll for more convenient use.

6. Action for Decoder Toolbar - Various buttons on this toolbar provide context-sensitive shortcuts for

decoding.

Search allows quick creation of a zoom trace and changes the dialog box to the zoom/search dialog
box.

Acquire long records of message data, and use Search to look through the record for a specific
message. When the message meeting the search criteria is found, the complete message is then
shown with the Zoom Trace. Use the arrow buttons to navigate forward and backward through the
messages. Unsuccessful searches are noted with a line of text.

Configure Table displays a pop-up dialog box specific to a particular protocol. The dialog contains
checkboxes for various columns in the table. Check or uncheck the checkboxes to show or hide
specific columns on the table.

Export Table exports the complete protocol table data to a .CSV file.

The Output File name and directory can be selected by the user using the controls to the right.
Click the Browse button to select a file.

Note: If you have the PROTObus MAG toolkit option, those screens are easily accessed from the Decode Setup