Serial data debug solutions 114 – Teledyne LeCroy Serial Data Debug Solutions User Manual
Page 114
![background image](/manuals/353669/114/background.png)
Serial Data Debug Solutions
114
919586 RevA
TxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition,
Value, To (for range conditions), and T/R controls. Word Count/Mode Code fields include Condition and
Word Count (amount) controls.
RxCmd2 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition,
Value, To (for range conditions), and T/R controls. Word Count/Mode Code fields include Condition and
Word Count (amount) controls.
DW Right-Hand Dialog - Provide Data Pattern Setup field values for Data Condition,Start Bit and # Data
Bits, Data Value and Data Value To (for range conditions).
TxStat1 Right-Hand Dialog - Provide RT Address field values for Condition, Value and To (for range
conditions). Select Status Word Setup values (0, 1, or X) for Error, Instr, SRQ, Bcast Rcvd, Busy, Sub Syst,
Dyn Bus, and Term Flg.
Mode command (B'cast) Sub-Type and Right-Hand Dialogs
When the Mode command (B'cast) sub-type is selected, the TxCmd1 right-hand dialog is made available.
Note: Different combinations of similar right-hand dialogs are made available for the various Sub-Types. See
BC-RT (Rcv) Sub-Type Right-Hand Dialogs
for screen-shots. Otherwise, provide field information as directed
verbally.
TxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition,
Value, To (for range conditions), and T/R controls. Word Count/Mode Code fields include Condition and
Mode Code controls. Select from 32 possible Mode Code values:
Mode Code Field Values
Dynamic Bus
Control
Synchronize
Transmit Status
Word
Initiate Self Test
Transmitter
Shutdown
Override
Transmitter
Shutdown
Inhibit
Terminal Flag
Override Inhibit
Terminal Flag
Reset Remote
Terminal
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Transmit
Vector Word
Synchronize
Transmit Last
Command
Transmit BIT
Word
Selected
Transmitter
Shutdown
Override Selected
Transmitter
Shutdown
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Mode command & Data (B'cast) Sub-Type and Right-Hand Dialogs
When the Mode command & Data (B'cast) sub-type is selected, the RxCmd1 and DW right-hand dialogs are
made available.
Note: Different combinations of similar right-hand dialogs are made available for the various Sub-Types. See
BC-RT (Rcv) Sub-Type Right-Hand Dialogs
for screen-shots. Otherwise, provide field information as directed
verbally.