Acyclic Data Transfer with
PROFIBUS, DeviceNet and CANopen

Bürkert mfc family Object

name

Description of the input
data attributes

attribute address
(class, instance
attribute; data type)

Slot, index

index, Subindex

Dvn

Dpv1

canopen

Binary
input 1
function

Read Write
determines the function of
binary input 1
(for a description see
"Operating Instructions")
min. value 0,
max. value 65535

dec: 110, 1, 40
Hex: 6E, 1, 28

UINT

dec: 1, 190
Hex: 1, BE

dec: 12288, 40
Hex: 3000, 28

UNSIGNEd16

Binary
input 2
function

Read Write
determines the function of
binary input 2
(for a description see
"Operating Instructions")
min. value 0,
max. value 65535

dec: 110, 1, 41
Hex: 6E, 1, 29

UINT

dec: 1, 191
Hex: 1, BF

dec: 12288, 41
Hex: 3000, 29

UNSIGNEd16

Binary
input 3
function

Read Write
determines the function of
binary input 3
(for a description see
"Operating Instructions")
min. value 0,
max. value 65535

dec: 110, 1, 42
Hex: 6E, 1, 2A

UINT

dec: 1, 192
Hex: 1, C0

dec: 12288, 42
Hex: 3000, 2A

UNSIGNEd16

Error pro-
cessing for
sensor-fault

Read Write
Error processing for sensor
error (see “9. Annex”)
min. value 0,
max. value 65535

dec: 110, 1, 43
Hex: 6E, 1, 2B

UINT

dec: 1, 193
Hex: 1, C1

dec: 12288, 43
Hex: 3000, 2B

UNSIGNEd16

Control
output y2

Read only
for MFC only. control output
y2 of controller in units per
thousand
min. value 0, max. value 1000

dec: 110, 1, 44
Hex: 6E, 1, 2C

UINT

dec: 1, 194
Hex: 1, C2

dec: 12288, 44
Hex: 3000, 2C

UNSIGNEd16

MFC mode

Read Write
Activation of the Autotune
function.
The controller must be in
normal mode.
(ModusMFC = 0)
Autotune can be activated by
writing a value of 2.

dec: 110, 1, 44
Hex: 6E, 1, 2C

UINT

dec: 1, 194
Hex: 1, C2

dec: 12288, 44
Hex: 3000, 2C

UNSIGNEd16

english

MFC Family