Burkert Type 8717 User Manual
Page 17

17
Serial Communication
command number
command name
0x80
readversion
request
Command
0x80
Byte count
0
data
-
response
Command
0x80
Byte count
36
2) 3) 4) 5)
Status
2 bytes, device status
data
34 bytes
0 – 1
device type (unsigned int), e.g. 8626
2
device number, z. B. 1
3 – 6
device Id number (unsigned long)
1)
7 – 10
device serial number (unsigned long)
1)
11 – 14 Software Id number (unsigned long)
1)
15
Software version x (x.y.z.cc): A – Z
16
Software version y (x.y.z.cc): 0 – 99
17
Software version z (x.y.z.cc): 0 – 99
18
Software version cc (x.y.z.cc): 0 – 99
19
EEPROM layout version x (x.y): A – Z
2)
20
EEPROM layout version y (x.y): 0 – 99
2)
21
Table_x version (x.y): A – Z
3)
22
Table_y version (x.y): 0 – 99
3)
23 – 26 Bios Id number (unsigned long)
4)
27
Bios version x (x.y.z.cc): A – Z
4)
28
Bios version y (x.y.z.cc): 0 – 99
4)
29
Bios version z (x.y.z.cc): 0 – 99
4)
30
Bios version cc (x.y.z.cc): 0 – 99
4)
31
MFi software version x (x.y): A – Z
5)
32
MFi software version y (x.y): 0 – 99
5)
33
MFi software version x (x.y): A – Z
5)
Description
Command to read device information and the software version.
1)
First byte transferred: LSB
2)
Version-dependent – available with firmware version A.00.29.02 or later
3)
Version-dependent – available with firmware version A.00.63.00 or later
4)
Version-dependent – available with firmware version A.00.64.00 or later
5)
Version-dependent – available with firmware version A.00.83.03 or later