Burkert Type 0312 User Manual
Burkert Accessories for water
Operating Instructions
Type 0311/0312
Design:
2-way solenoid valve, direct acting, normally closed (Circuit
function C), normally open (Circuit function D) or mixer
function (Circuit function E).
Seal Materials and Fluids handled:
See Table.
Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature
104 °F (40 °C)
Max. Fluid Temperature
194 °F (90 °C)
For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature
104 °F (40 °C)
Max. Fluid Temperature
140 °F (60 °C)
For Hazardous Locations Div. 2 and Ordinary Locations:
See Table.
Pressure Range:
Maximum inlet pressure see label on valve.
Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, seal materials, welding scale etc.). Instal-
lation as required but preferably with coil uppermost. Installation
in this position tends to prevent foreign matter remaining in core
tube (increased life). Do not put any loads on coil unit.
Type 0311: PTFE tape is recommended for sealing ports.
Mounting is accomplished by means of four M4 x 8 mm tapped
holes located on the valve underside.
Type 0312: Ports A (B) are coded on side of body. For common
pressure, align "A (B)" marking on valve and manifold. Valve
operation C and D valves cannot be manifolded together. To
remove valve from manifold loosen only the two unsealed screws.
Manifolds can be connected togehter with nipples.
Marking (example):
Circuit function
C
=
Normally Closed
D
=
Normally Open
E
=
Mixer Function
Seal Material
EPDM
=
EPDM
NBR
=
NBR
FKM
=
FKM
EA
=
PTFE seat and EPDM O-ring
EF
=
PTFE seat and FKM O-ring
NN
=
Neoprene
RF
=
Ruby seat and FKM O-ring
Body Material
BR
=
Brass
SS
=
Stainless Steel
NI
=
Nickel Plated Brass
PL
=
Polyamide Plastic
Maximum Pressure
Voltage / Frequency / Power Consumption
Recorder No.
Approvals
The valve is either approved as
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4
or
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6
or
FM approved as
Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4
UL listed for Ordinary locations
CSA approved for Ordinary locations
See label on the valve.
Operating Instructions 0605/08_EU-EN_00893135
Seal Materials Seat / O-ring
Fluid
Tempera-
tures [° F]
Buna „N‰
Ethylene
Propylene
FKM
PTFE/
Ethylene
Propyl.
PTFE/
FKM
Neoprene
Air
Fluid T.
Ambient
+14 to +194
+14 to +130
- 40 to +266
+14 to +130
+14 to +266
+14 to +130
+14 to +266
+14 to +130
+14 to +266
+14 to +130
Water
Fluid T.
Ambient
+32 to +194
+32 to +130
+32 to +212
+32 to +130
+32 to +212
+32 to +130
+32 to +212
+32 to +130
+32 to +212
+32 to +130
Neutral Gas
Fluid T.
Ambient
+14 to +194
+14 to +130
- 40 to +266
+14 to +130
+14 to +266
+14 to +130
+14 to +266
+14 to +130
+14 to +266
+14 to +130
Light oil
Fluid T.
Ambient
+14 to +194
+14 to +130
+14 to +266
+14 to +130
+14 to +266
+14 to +130
LP-gas
Fluid T.
Ambient
+14 to +140
+14 to +130
+14 to +140
+14 to +130
+14 to +140
+14 to +130
Refrigerants
Fluid T.
Ambient
+14 to +194
+14 to +130
Voltage 12V or 24V
UL / UR valid with
class 2 power supply only