beautypg.com

Burkert Type 0312 User Manual

Burkert Accessories for water

background image

Operating Instructions

Type 0311/0312

Design:
2-way solenoid valve, direct acting, normally closed (Circuit
function C), normally open (Circuit function D) or mixer
function (Circuit function E).

Seal Materials and Fluids handled:
See Table.

Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

194 °F (90 °C)

For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

140 °F (60 °C)

For Hazardous Locations Div. 2 and Ordinary Locations:
See Table.

Pressure Range:
Maximum inlet pressure see label on valve.

Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, seal materials, welding scale etc.). Instal-
lation as required but preferably with coil uppermost. Installation
in this position tends to prevent foreign matter remaining in core
tube (increased life). Do not put any loads on coil unit.

Type 0311: PTFE tape is recommended for sealing ports.
Mounting is accomplished by means of four M4 x 8 mm tapped
holes located on the valve underside.

Type 0312: Ports A (B) are coded on side of body. For common
pressure, align "A (B)" marking on valve and manifold. Valve
operation C and D valves cannot be manifolded together. To
remove valve from manifold loosen only the two unsealed screws.
Manifolds can be connected togehter with nipples.

Marking (example):

Circuit function
C

=

Normally Closed

D

=

Normally Open

E

=

Mixer Function

Seal Material
EPDM

=

EPDM

NBR

=

NBR

FKM

=

FKM

EA

=

PTFE seat and EPDM O-ring

EF

=

PTFE seat and FKM O-ring

NN

=

Neoprene

RF

=

Ruby seat and FKM O-ring

Body Material
BR

=

Brass

SS

=

Stainless Steel

NI

=

Nickel Plated Brass

PL

=

Polyamide Plastic

Maximum Pressure

Voltage / Frequency / Power Consumption

Recorder No.

Approvals
The valve is either approved as

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4

or

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6

or

FM approved as

Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4

UL listed for Ordinary locations
CSA approved for Ordinary locations

See label on the valve.

Operating Instructions 0605/08_EU-EN_00893135

Seal Materials Seat / O-ring

Fluid

Tempera-
tures [° F]

Buna „N‰

Ethylene
Propylene

FKM

PTFE/
Ethylene
Propyl.

PTFE/
FKM

Neoprene

Air

Fluid T.

Ambient

+14 to +194
+14 to +130

- 40 to +266
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

Water

Fluid T.

Ambient

+32 to +194
+32 to +130

+32 to +212
+32 to +130

+32 to +212
+32 to +130

+32 to +212
+32 to +130

+32 to +212
+32 to +130

Neutral Gas

Fluid T.

Ambient

+14 to +194
+14 to +130

- 40 to +266
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

Light oil

Fluid T.

Ambient

+14 to +194
+14 to +130

+14 to +266
+14 to +130

+14 to +266
+14 to +130

LP-gas

Fluid T.

Ambient

+14 to +140
+14 to +130

+14 to +140
+14 to +130

+14 to +140
+14 to +130

Refrigerants

Fluid T.

Ambient

+14 to +194
+14 to +130

Voltage 12V or 24V

UL / UR valid with

class 2 power supply only

This manual is related to the following products: