Burkert Type 0255 User Manual
Operating instructions type 0255
Operating Instructions
Type 0255
Recorder No.
Voltage / Frequency / Power Consumption
Maximum Pressure
Marking (example):
Body Material
BR
=
Brass
SS
=
Stainless Steel
Seal Material
EPDM
=
EPDM
NBR
=
NBR
FKM
=
FKM
EA
=
PTFE seat and EPDM O-ring
EF
=
PTFE seat and FKM O-ring
CF
=
FFKM seat and FKM O-ring
Circuit function
A =
Normally Closed
Design:
2-way solenoid valve, direct acting, normally closed (Circuit
function A).
Seal Materials and Fluids handled:
See Table.
Fluid and Ambient Temperature:
See Table.
Pressure Range:
Maximum inlet pressure see label on valve.
Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, seal materials, welding scale etc.). Instal-
lation as required but preferably with coil uppermost. Installati-
on in this position tends to prevent foreign matter remaining in
core tube (increased life). Do not put any loads on coil unit.
Type 0255: PTFE tape is recommended for sealing ports.
Arrow on valve body indicates flow direction. Mounting is
accomplished by 2 holes 6.5 mm thru valve body.
Operating Instructions 0605/08_EU-EN_00893149
Seal Materials
Fluid
Tempera-
tures [° F]
Buna „N‰
Ethylene
Propylene
FKM
Steel
PTFE
FFKM
Air
Fluid T.
Ambient
+ 14 to + 194
+ 14 to + 130
- 40 to + 266
+ 14 to + 130
+ 14 to + 266
+ 14 to + 130
- 40 to + 356
+ 14 to + 130
- 40 to + 356
+ 14 to + 130
+ 14 to + 266
+ 14 to + 130
Water
Fluid T.
Ambient
+ 50 to + 194
+ 32 to + 130
+ 50 to + 212
+ 32 to + 130
+ 50 to + 212
+ 32 to + 130
+ 50 to + 212
+ 32 to + 130
+ 50 to + 212
+ 32 to + 130
+ 50 to + 212
+ 32 to + 130
Neutral Gas
Fluid T.
Ambient
+ 14 to + 194
+ 14 to + 130
- 40 to + 266
+ 14 to + 130
+ 14 to + 266
+ 14 to + 130
- 40 to + 356
+ 14 to + 130
- 40 to + 356
+ 14 to + 130
+ 14 to + 266
+ 14 to + 130
Light oil
Fluid T.
Ambient
+ 50 to + 194
+ 14 to + 130
+ 50 to + 194
+ 14 to + 130
+ 50 to + 194
+ 14 to + 130
+ 50 to + 194
+ 14 to + 130
+ 50 to + 194
+ 14 to + 130
LP-gas
Fluid T.
Ambient
+ 14 to + 140
+ 14 to + 130
+ 14 to + 140
+ 14 to + 130
+ 14 to + 140
+ 14 to + 130
+ 14 to + 140
+ 14 to + 130
+ 14 to + 140
+ 14 to + 130
Steam
Fluid T.
Ambient
+ 212 to + 266
+ 14 to + 130
+ 212 to + 266
+ 14 to + 130
+ 212 to + 356
+ 14 to + 130
+ 212 to + 356
+ 14 to + 130
+ 212 to + 266
+ 14 to + 130
Voltage 12V or 24V
UL / UR valid with
class 2 power supply only