Burkert Type 0280 User Manual
Operating instructions type 0280
Operating Instructions
Type 0280
Recorder No.
Voltage / Frequency / Power Consumption
Maximum Pressure
Marking (example):
Body Material
BR
=
Brass
SS
=
Stainless Steel
NI
=
Nickel Plated Brass
PL
=
Polyamide Plastic
Seal Material
EPDM
=
EPDM
NBR
=
NBR
FKM
=
FKM
Circuit function
A
=
Normally Closed
B
=
Normally Open
Operating Instructions 0605/08_EU-EN_00893133
Approvals
The valve is either approved as
General Purpose valve for Hazardous Locations
Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4
or
FM approved as
Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4A
or
UL listed for Ordinary locations
or
CSA approved for Ordinary locations
See label on the valve.
Design:
2-way solenoid valve, internally piloted, normally closed
(Circuit function A) or normally open (Circuit function B).
Seal Materials and Fluids handled:
See Table.
Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature
104 °F (40 °C)
Max. Fluid Temperature
194 °F (90 °C)
For Hazardous Locations Div. 2 and Ordinary Locations:
See Table.
Pressure Range:
Minimum pressure differential between and outlet port is 7 PSI.
Maximum inlet pressure see label on valve.
Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal fillings, sealing materials, welding scale etc.).
PTFE tape is recommended for sealing ports. Arrow on valve
body gives flow direction. Installation as required but
preferably with coil uppermost. Installation in this position
tends to prevent foreign matter remaining in pilot valve
(increased life). A strainer upstream of valve, protects
against effects of foreign matter. Do not put any loads on coil
unit. Pipework should be supported such that valve body is
not under strain. Do not allow a pipe-end or sealing material
to block the pilot bore within the valve outlet. Inlet and outlet
of valve must be fullbore and pipework unrestricted.
Seal Materials Seat/O-ring
Fluid
Temperatures [° F]
Buna „N‰
Ethylene
Propylene
FKM
Air
Fluid T.
Ambient
+ 14 to + 194
+ 14 to + 130
- 40 to + 194
+ 14 to + 130
+ 14 to + 194
+ 14 to + 130
Water
Fluid T.
Ambient
+ 32 to + 194
+ 32 to + 130
+ 32 to + 194
+ 32 to + 130
+ 32 to + 194
+ 32 to + 130
Neutral Gas
Fluid T.
Ambient
+ 14 to + 194
+ 14 to + 130
- 40 to + 194
+ 14 to + 130
+ 14 to + 194
+ 14 to + 130
Light oil
Fluid T.
Ambient
+ 14 to + 194
+ 14 to + 130
+ 14 to + 194
+ 14 to + 130
LP-gas
Fluid T.
Ambient
+ 14 to + 140
+ 14 to + 130
+ 14 to + 140
+ 14 to + 130
Voltage 12V or 24V
UL / UR valid with
class 2 power supply only