25

Serial Communication

command number
command name
Device types

0x98
extSetpointwithoutanswer
0xee

request
Command

0x92

Byte count

5

data

1 byte
0

Set-point value settings, internal

1

Set-point value settings, external

4 bytes
1 – 4

Set-point value [%] (float)

1)

response
Command

-

Byte count

-

Status

-

data

-

Description

Available as of firmware version A.00.51.06.

determines the set-point value settings and describes the external set-point value as a percentage:
Internal = analog - the set-point value settings is assigned by the analog

set-point value signal that is created

External = digital via serial interface

do not use this command if you are using a bus device (PROFIBUS, deviceNet, etc.). The digital set-point
value settings via the serial interface has a higher priority.

No response is sent for this command.

1)

First byte transferred: MSB

english