CANopen Start-up

The bit field can be defined by SdO access.

Id

dLC

Byte0

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

600h+Id

8

22

4200H

01H

Bit field

6.4.2.

Transmitted pDOs

Transmitted PdOs are data that has been sent to the device (MFC). This is input data as seen by the PLC.

transmitted pDO

Byte

txpDO0

txpDO1

txpDO2

txpDO3

0

Byte 0

Actual

value

Byte 0

Status

limits

Byte 0

Totalizer

(of the

active gas)

Byte 0

Actual value

as Float

1

Byte 1

Byte 1

Byte 1

Byte 1

2

Byte 0

Set-

point

value

Byte 0

Status

others

Byte 2

Byte 2

3

Byte 1

Byte 1

Byte 3

Byte 3

4

Byte 0

Active

gas

Byte 0

AddMea-

sureValue

Byte 0

Flow rate

(of the

active gas)

Byte 0

Set-point

value as

Float

5

Byte 1

Byte 1

Byte 1

Byte 1

6

Byte 0

Status

errors

Byte 2

Byte 2

Byte 2

7

Byte 1

Byte 3

Byte 3

Byte 3

The following bit field makes it possible to select objects for the process data transfer.

english

MFC Family