Description of system
11.3. specifications of the positioner
11.3.1. conformity
In accordance with the EC Declaration of conformity, the positioner Type 8692 and 8693 are compliant with the
EC Directives.
11.3.2. standards
Conformity with the EC Directives is verified by the following standards.
EN 61000-6-3, EN 61000-6-2, EN 61010-1
11.3.3. Operating conditions
caution!
Solar.radiation.and.temperature.fluctuations.may.cause.malfunctions.or.leaks.
• If the device is used outdoors, do not expose it unprotected to the weather conditions.
• Ensure that the permitted ambient temperature does not exceed the maximum value or drop below the mini-
mum value.
Ambient temperature
0 – + 55 °C
Protection class
IP 65 / IP 67 in accordance with EN 60529
(only if cables, plugs and sockets have been connected correctly and in
compliance with the exhaust air concept in chapter “17.3. Pneumatic connection of
the positioner“)
11.3.4. mechanical data
Dimensions
see data sheet
Body material
exterior: PPS, PC, VA, interior: PA 6; ABS
Sealing material
NBR / EPDM
Stroke range of valve spindle 3 – 28 mm
11.3.5. electrical data
Connections
cable gland (24 V DC) or
circular plug-in connector (Profibus DP, DeviceNet, 24 V DC)
Supply voltage
24 V DC ± 10 % max. residual ripple 10 %
Power input
< 5 W