DeviceNet
41.
elecTrical cOnnecTiOns
danGer!
Danger.-.electrical.voltage.in.the.equipment!
There is a serious risk of injury when reaching into the equipment.
• Before starting work, always switch off the power supply and safeguard to prevent re-activation!
WarninG!
Danger.-.improper.installation!
Improper installation may result in injuries as well as damage to the device and the area around it.
• Fluid and electrical installations may be carried out by authorised technicians only and with the appropriate
tools!
Danger.due.to.unintentional.activation.of.the.equipment!
Unintentional activation of the equipment during installation may result in injuries and damage.
• Take appropriate measures to prevent the equipment from being unintentionally activated.
→
For operation of the device always connect the 5-pole (bus) and the 4-pole M12 circular plug (supply
voltage).
The connection module of Type 8692 and 8693 features a setscrew with nut which is used to connect the function earth
(see “Figure 120: “).
→
Connect the setscrew to a suitable earthing point.
To ensure electromagnetic compatibility (EMC), ensure that the cable is as short as possible
(max. 30 cm, Ø 1.5 mm
2
).
41.1. connection diagram Type 8692
Circular.plug.M12,.5-pole
DeviceNet
Function earth (FE)
1
2
3
4
Circular.plug.M12,.4-pole
Supply voltage
1
2
3
4
5
Figure 120: Connection of DeviceNet - Type 8692
english
Type 8692, 8693