Disassembly
2. Electrical connection
danGer!
risk.of.electric.shock!
• Before reaching into the device or the equipment, switch off the power supply and secure to prevent
reactivation!
• Observe applicable accident prevention and safety regulations for electrical equipment!
Circular plug-in connector:
→
Loosen the circular plug-in connector.
Cable gland:
→
Unscrew the 4 screws on the cover and remove the cover.
→
Unscrew the screw terminals and pull out cables.
→
Close the positioner.
3. Mechanical connection
→
Loosen the fastening screws.
→
Remove the positioner upwards.
Pneumatic
connections
Positioner
Actuator
Cover
electrical connection
cable gland
Fastening
screws (2x)
Pneumatic con-
nection to the
actuator
Actuator
Electrical
connection
circular
plug-in
connector
Series 2103, 2300 and 2301
Series 26xx and 27xx
Figure 132: Disassembly the positioner