DeviceNet
name
Description.of.the.input.data.attributes
Attribute.Address.
Class,.Instance,.
Attribute;..
Data.type,.Length
POS
Actual position
Actual value of position controller as ‰. Value range 0–1000.
However, values <0 or >1000 also possible if e.g. Autotune has
not run through correctly.
111, 1, 59;
INT, 2 byte
CMD
Nominal position
Set-point value of position controller as ‰. Value range 0–1000.
111, 1, 58;
UINT, 2 byte
PV
78)
Process actual value (process value)
Actual value of process controller in physical unit (as set in the
menu
P.CO INP or P.CO SCAL), max. value range –999–9999,
depending on internal scaling.
120, 1, 3;
INT, 2 byte
SP
78)
Process set-point value
Set-point value of process controller in physical unit (as set in the
menu
P.CO INP or P.CO SCAL), max. value range –999–9999,
depending on internal scaling.
120, 1, 2;
INT, 2 byte
ERR
Error
Indicates the number of the process value (output) which was not
written. The value is retained until it is deleted with “1” by acycli-
cally writing the “Error” attribute (access via Explicit Message –
Set Attribute Single).
HEX
0X14 INP
0X15 SP
100, 1, 1;
USINT, 1 byte
Table 54:
78)
relevant only for type 8693 and when process controller activated.