Parameter

Description

SLICER Section

MODE

Here you can select either

Split

,

Grid

,

Detect

or

Manual

:

Detect mode: The Sample will be sliced according to its transients.
Split mode: The Sample will be sliced into equally spread Slices.
Grid mode: The Sample will be sliced according to note values.
Manual mode: Manually enter slice points using the pads on your
controller, or adjust the start and end points of a slice.

SLICES

(Split and

Grid mode only)

When

MODE

is set to

Split

(see above),

SLICES

lets you choose the

amount of Slices: 4, 8, 16 or 32.
When

MODE

is set to

Grid

(see above),

SLICES

lets you choose the

length of the Slices in note values: 4th, 8th,16th or 32nd notes.

AUTO-SNAP

(Manual

mode only)

The Sample Slicer Manual mode Auto-Snap feature automatically

aligns Slice points to the nearest transient as you manually trigger

the slicing from the pads. It can be turned off so that slice points are
instead placed exactly where you trigger them. In order to use Auto-

Snap, you must wait for analysis to be performed on the sample
you’re slicing—the analysis is very quick but will take longer for long
audio files.

SENSITIVITY

(Detect

mode only)

When

MODE

is set to

Detect

(see above),

SENSITIVITY

lets you

adjust the sensitivity of the transient detection. Higher values will
cause more Slices to be detected because more transients will be

recognized, lower values will result in less Slices. This parameter
should be adjusted until all the musically significant slices are being

detected in the waveform.