Showresultsgraphics – Adept AdeptSight Reference Guide User Manual
Page 461
ShowResultsGraphics
VPARAMETER
150
When enabled, vision results are displayed in the image display control. When disabled, vision results are
not displayed.
Syntax
Micro V+
VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) = value
value = VPARAMETER (sequence_id, tool_id, 150, index_id, object_id)
V+
VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) $ip = value
value = VPARAMETER ($ip, sequence_id, tool_id, 150, index_id, object_id)
Type
Boolean
Range
Value
Description
1
Enabled: Vision results are displayed in the image display control.
0
Disabled: Vision results are not displayed.
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ID
150: the value used to reference this property.
index_id
N/A
object_id
N/A
ShowResultsGraphics
AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012